By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. Refer to After pressing enter you have to assign the "FROM" fields to the "TO" fields. The function delivered in this version is based upon the enhancement requests from a specific group of users. The spaces really do you a favor by causing the SOC7 (Numeric Exception) on the intermediate arithmetic fields. On the other hand, you can use the NumVal (or NumVal-C) intrinsic functions (with any compiler supporting the '89 ANSI/ISO amendment) to the "numeric" values of an alphnanumeric field that contains spaces, decimal points, comma, (or with NumVal-C) currency signs. To learn more, see our tips on writing great answers. previous tip, SSIS offers us the possibility to extend its functionality by the COBOL Routine for Example-104 byte [] pd = args [0] .getBytes () will build a byte array = {0x11, 0x23, 0x4D} this will result in -11234. GnuCOBOL (formerly OpenCOBOL) is a COBOL compiler with run time support. The status of each job step may be tested at the end of each job step. Get alphanumeric string redefined into two numeric fields to hold and process decimal part and integer part individually. In my use case I had to use suggestion from both of your posts. Not the answer you're looking for? I just wanted to know, do we have any tool or utility through which we can do the same. There are letter characters aside from sign character inside Comp-3 value, How to process mainframe numbers where "{" is the last character. To 02 FEC-SS PIC X(2). the hex number 0x48. Required fields are marked *. Add a comment. This group of test cases will show the process for converting a BINARY numeric format (COMPUTATIONAL or COMP) to a display format. I've written a package just like this one and the packed fields are importing just fine. 02 CONVAL2-OUT PIC X(8). Implement Seek on /dev/stdin file descriptor in Rust, Follow Up: struct sockaddr storage initialization by network format-string. Explore Numeric formats include Binary, Packed Decimal and Zoned Decimal. Another instance of Visual 02 OPERADOR-OUT PIC X. Asusually, I could find out a way to achieve it! and view the COBOL source code for this numeric field conversion example. What sort of strategies would a medieval military use against a fantasy giant? Find centralized, trusted content and collaborate around the technologies you use most. To convert that field in Easytrieve Plus, you'd need to write some code, a loop starting at the right, ignoring blanks. about the data types just in case you dont know about Cobols syntax. For eg., i have alphanumeric string and select {CR}{LF} as the row delimiter like on the next image. It consists of the word PIC or PICTURE followed by the actual picture clause, where the type and size are specified. 01 WS-ZONED-DECIMAL PIC S9 (11)V99. else that would make our package end with an error. How do/should administrators estimate the cost of producing an online introductory mathematics class? one with a leading sign and a decimal point). Calculation for length: PD= 5 bytes Length= ( (2 x PD) -1) = (2x 5) -1 = 9 bytes. A packed decimal representation stores decimal digits in each "nibble" of a byte. transformation. Unpack. > our case can be any number from 0 - 199). Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? This program (NBRCVTC3.cbl) was written to show various techniques for converting between various Zoned-Decimal numeric field formats used on the mainframe and/or with the COBOL programming language. Not the answer you're looking for? How do you get out of a corner when plotting yourself into a corner, Linear Algebra - Linear transformation question. So the comp-3 field of size 4 bytes can store an numeric digits of +999,9999 to -999,9999 digits. Using DFSORT OUTREC options you can achieve the same. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact, Comment or Feedback section of this document. Then setup the flat file connection with a fixed width format, an ANSI code page The combined scores of. Moving packed-decimal (PIC S9(11)V99 COMP-3) to zoned-decimal (PIC S9(11)V99) is completely valid - providing the comp-3 data is properly signed numeric. Please suggest. one digit per byte. To convert from zoned to packed. This suite of test cases describes how to convert between the various numeric formats (or data types such as DISPLAY, COMP, COMP-3 or DECIMAL, BINARY and PACKED) used with COBOL and on an IBM Mainframe System. To change this to readable format, you need to convert these numbers into ZONED Decimal (ZD) format. Staging Ground Beta 1 Recap, and Reviewers needed for Beta 2, How do I convert an integer value to decimal value in COBOL. Little Endian - within a sixteen or thirty-two bit word the bytes at lower addresses have lower significance. This link requires an Internet Connection. Re: convert 1 BYTE binary to decimal in cobol. Comp-3 is a common data type, even outside of COBOL, and is fairly standard across platforms -- that is, it is not . 01 WS-BINARY PIC S9 (11)V99 COMP. Using Kolmogorov complexity to measure difficulty of problems? I am unsure of the correct interpretation of the following field definitions and was hoping someone would know: FIELD-NAME-1 PIC S9(15)V9(3) COMP-3. AC Op-amp integrator with DC Gain Control in LTspice, Follow Up: struct sockaddr storage initialization by network format-string, How do you get out of a corner when plotting yourself into a corner, Trying to understand how to get this basic Fourier Series. After I import the binary file, and choose DT_STR as data type and add the field to the VB script, the output looks just like the weird binary characters in the file. Script Component has encountered an exception in user code : Project name: SC_502c8f1c0d6b40d7929990353c01db83, at System.Data.SqlTypes.SqlDecimal.ConvertToPrecScale(SqlDecimal n, Int32 precision, Int32 scale), at Microsoft.SqlServer.Dts.Pipeline.PipelineBuffer.SetDecimal(Int32 columnIndex, Decimal value), at Microsoft.SqlServer.Dts.Pipeline.PipelineBuffer.set_Item(Int32 columnIndex, Object value), at Microsoft.SqlServer.Dts.Pipeline.ScriptBuffer.set_Item(Int32 ColumnIndex, Object value), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.ScriptMain.Input0_ProcessInputRow(Input0Buffer Row), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.UserComponent.Input0_ProcessInput(Input0Buffer Buffer), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.UserComponent.ProcessInput(Int32 InputID, PipelineBuffer Buffer), at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.ProcessInput(Int32 inputID, PipelineBuffer buffer). At the end of the exercise variable Y contains something that is readable and makes sense to the normal human eye. I believe, the receiving fields should be 'STRING's too. I know two methods for doing that. Yes . The following is the WORKING-STORAGE definition for the source field. For example, I have a 2 character field with value of PR. S9(15) means a 15 digit numeric signed field: S for sign, 9 is numeric, (15) is length. Each byte has two nibbles, and each nibble is indicated by a hexadecimal character. Enter 2 and 3 in the TO section of the panel, for example:CA File Master Plus -- Reformat your.CONVERT.LIB(REFORMAT) COMMAND ===> SCROLL ===> CSR FROM Record ------------ CPYBK#O1 of your.CONVERT.LIB --------------Num Field Name Pos Format Row 1 of 3 1 DATAREC1OLD 1 78 2 FIELD1-PCK 1 P 8.2 3 FILLER 7 C 72 *************************** Bottom of Record Layout *************************** TO Record ------------ CPYBK#N1 of your.CONVERT.LIB --------------Num Field Name Pos Format Reformat Row 1 of 3 1 DATAREC1NEW 1 80 2 FIELD1-NUM 1 N 6.2 2 3 FILLER 9 C 72 3 *************************** Bottom of Record Layout ***************************After pressing enter the numbers will be automatically translated to the field names.Press PF3 and type E now.You will see the JCL now. The Result field is also defined with a SIGN TRAILING SEPARATE that creates an additional byte to the field for the sign. A suite of Bash Script Files is provided to run the jobs on a Linux or UNIX System with GnuCOBOL (formerly known as Open COBOL) being used to compile and execute the COBOL Programs. Connection to the file created in the previous step and an OLEDB connection to our Then I have the script component output parameter set to DT_NUMERIC with a precision of 7 and scale of 2. What you probably need to do is something along the lines of: Yes, the above program uses an additional variable in the middle to convert numeric format to display format, but that is exactly how the language was designed. to handle the columns as binary data. Each byte has two nibbles, and each nibble is indicated by a hexadecimal character. Each picture character represents one . also, I create a script task that create the package at run time to load and convert Comp-3 and Comp fields. This is an EBCDIC encoded environment. When you want to move a value from one Numeric/Packed/Binary variable to another Numeric/Packed (COMP-3) /Binary (COMP) variable, never use the MOVE verb. This document describes how packed decimal values (Computational-3) can be converted to numeric values via File Master using COBOL copybooks. Beware, I haven't run this through a compiler! In the world of programming there are many ways to solve a problem. Handling the case of the 10th digit being 9 is a trivial IF statement. Which worries me, those should require 10 bytes. FIELD-NAME-2 PIC S9(3)V9(8) COMP-3. Explanation: For a comp-3 packed field specifies the number of digits after unpacking. Atlast divide the decimal-total by 1000 and add it to integer-part. Format: label PACK D 1 (L 1 ,B 1 ),D 2 (L 2 ,B 2 ) - Packs the L 2 byte zoned decimal number at D 2 (B 2 ) and stores it as a L 1 byte packed decimal number at D 1 (B 1 ) - The packing process: 1. The Source Field is defined as a Zoned-Decimal (or USAGE IS DISPLAY) field with 5 digits and zero decimal positions. To change this to readable format, you need to convert these numbers into ZONED Decimal (ZD) format. I need to be able to write a file that contains binary data. Anyhow thanks for your interest and response Gilbert. The sign indication is dependent on your operating environment. copybooks. Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com, 104, Packed Field, Explicit Decimal Point, 204, Binary Field, Explicit Decimal Point.